WATER QUALITY MULTI PARAMETER
pH/ ORP/ Conductivity/ ° C/ ° F Meter
Type : BI.902P
 

 
 Specifications :
 pH Range :      -2.000~ 20.000pH
 pH Accuracy      :      ± 0.002pH
 Resolution      :      0.001, 0.01, 0.1pH, Selectable
 Calibration Points      :      Up to 5 points
 Calibration Solutions      :      USA( pH1.68/ 4.01/ 7.00/ 10.01/ 12.45) , NIST( pH1.68/ 4.01/ 6.86/ 9.18/ 12.45) , DIN( pH1.09/ 4.65/ 6.79/ 9.23/ 12.75)
 mV Range      :      -1999.9~ 1999.9mV
 mV Accuracy      :      ± 0.2mV
 Resolution      :      0.1, 1mV, Selectable
 Conductivity Range      :      0~ 20mS/ cm ( Max.200mS/ cm)
 Conductivity Accuracy      :      ± 0.5% Full Scale
 Calibration Points      :      Up to 5 points
 Calibration Solutions      :      10uS/ cm, 84uS/ cm, 1413uS/ cm, 12.88mS/ cm, 111.8mS/ cm
 TDS Range      :      0~ 10ppt ( Max. 20ppt, Depending on factor setting)
 TDS Accuracy      :      ± 1% Full Scale
 TDS Factor      :      0.1~ 1.0 ( Default 0.5)
 Salinity Range      :      0~ 10ppt ( Max.80ppt)
 Salinity Accuracy      :      ± 1% Full Scale
 Salinity Measurement Modes      :      Practical Salinity ( PSU) or Seawater Measurement Standard ( ppt)
 Resistivity Range      :      0~ 100M©
 Resistivity Accuracy      :      ± 1% Full Scale
 Temperature Coefficient      :      0.0~ 10.0% per ° C
 Compensation Modes      :      Linear or Pure Water
 Cell Constant      :      K= 0.1, 1, 10, Selectable
 Normalization Temperature      :      20° C or 25° C
 Temperature Range      :      0~ 105° C, 32~ 221° F
 Temperature Accuracy      :      ± 0.5° C, ± 0.9° F
 Temperature Calibration      :      Manual
 Temperature Compensation      :      0~ 100° C, 32~ 212° F, Automatic or Manual
 Auto-Off      :      Manual or Automatic ( 10, 20, 30 minutes after last key pressed, Selectable)
 Hold Function      : Manual or Automatic
 Stability Conditions      :      Low or High, Selectable
 Calibration due reminder      :      0 to 30 days
 Reset Function      :      Yes
 Memory      :      500 data sets with Date/ Time stamping
 Output      :      USB Communication Interface
 Connector      :      BNC and 6-pin connector
 Power Requirements :      3× 1.5V " AA" Batteries
 Battery Life      :      Approximately 150 hours
 Dimensions      :      170( L) × 85( W) × 30( H) mm
 Weight      :      300 grams